ROHDE & SCHWARZ NRV-Z4 CALIBRATION and ROHDE & SCHWARZ NRV-Z4 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ NRV-Z4 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   ROHDE & SCHWARZ NRV-Z4 (828.3618.02)   Description / Specification:    
ROHDE & SCHWARZ NRV-Z4 6 GHz High-Sensitivity Diode Sensor

The Rohde & Schwarz NRV-Z4 is a high-sensitivity power sensor based on zero-bias Schottky diodes, this opens up the power range below 1 µW down to the physical limit of 100 pW (-70 dBm). In the range, from -70 dBm to -20 dBm, it's behaviour is much the same as that of thermal sensors, i.e. precise measurement of the average power of modulated signals, RMS weighting of harmonics and linearity independent of temperature and frequency. Specifications. Frequency range: 100 kHz to 6 GHz. Power measurement range, max. power: 100 pW to 20 mW, 100 mW (AVG), 100 mW (PK). Max. SWR (reflection coefficient): 0.1 MHz to 100 MHz 1.05 (0.024), >1 GHz to 2 GHz 1.10 (0.048), >2 GHz to 4 GHz 1.20 (0.09), >4 GHz to 6 GHz 1.35 (0.15). Zero offset: ±50 pW. Display noise: 20 pW. Linearity uncertainty: 0.03 dB (0.7%). Power coefficient: 0. Connector: Type N, 50 ohm.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ NRV-Z4. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

White Noise
White noise is noise whose power spectral density (watts/hertz) is constant for the frequency range of interest.


Please contact us for your ROHDE & SCHWARZ NRV-Z4 CALIBRATION and/or ROHDE & SCHWARZ NRV-Z4 6 GHz High-Sensitivity Diode Sensor REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: